Conductivity profiling is used to isolate and identify the source of conductivity problems in pressure vessels of a reverse osmosis unit. This method involves measuring the conductivity of the permeate stream at multiple points along the pressure vessel train to pinpoint the location of the problem.
Source: Membrane system design and operation references